Gas Detectors SafeCheck 200

SafeCheck 200 - Reliable

The SafeCheck 200 will measure and alarm for hazardous levels of oxygen and combustible gases. This is one of the most reliable gas detectors you can find.

Standard features include automatic one button calibration, a safety chirp to indicate to the user that the instrument is functioning, pulsating loud warning horn, flashing visual alarm indicators and an intelligent zero function that prevents the operator from zeroing in a contaminated environment.

Simple user selectable alarm levels are available for low/high O2 and LEL.

Remote sampling can easily be accomplished by the optional remote sample draw pump that will draw a sample in excess of 50 feet and uses the unit’s electronics to sense a flow restriction.

For pricing and availability information regarding the purchase, service or calibration of Quest products, please email Customer Service.

For the answers to questions regarding installation, setup, operation, maintenance or trouble-shooting of Quest products, please email Technical Support.

Brochures Available:
English Version (pdf) 1.45M
Spanish Version (pdf) 1.91M

SC200 Technical Specifications


Number of Sensor Channels:

  • Two

Display Type:

  • 2-Line Backlit LCD

Environmental:

  • Operating Temp. Range: 14 to 104®F (-10 to +40®C)
  • Storage Temp. Range: 5 to 140®F (-15 to +60®C)
  • Humidity Range: 0 to 90% RH, non-continuous, non-condensing
  • 15 to 90% RH continuous, non-condensing

Power:

  • Battery Life:
      Alkaline 16 Hrs.

Mechanical:

  • Case Material: ABS Polycarbonate & Nickel Alloy Plated
  • Size: 6.9 x 3.4 x 2.0" (17.5 x 8.6 x 5.1 cm)
  • Weight: 22 oz. (0.6 kg)

Applicable Standards:

  • Ingress Protection IP54
  • RFI/EMI Protection Rating ANSI C95. 1-1982 & EN50082-2
  • Intrinsic Safety: Class I,II,III Div. 1, Groups A,B,C,D,E,F,G
  • Eex ia IIC T4, MSHA 2G
  • Australia (SIMTARS)
  • CE Mark

Warranty Period:

  • 2 Yrs.